Transformer Bushing Monitoring System for Continuous Insulation Health Monitoring
Our online bushing monitoring system tracks total current, capacitance, dielectric loss and partial discharge on high-voltage transformer bushings around the clock — turning bushing insulation health, condition and status into live, actionable data instead of a once-a-year offline test result.
- Continuous capacitance, dielectric loss, leakage current and PD monitoring on live bushings
- IN-205B model series — insulation-only, PD-only, or fully integrated configurations
- Modbus / DL/T860 output for direct SCADA and substation automation integration
What Is a Transformer Bushing Monitoring System?
A transformer bushing monitoring system is an online monitoring platform used for insulation condition monitoring of high-voltage transformer bushings. It continuously measures total current, capacitance, dielectric loss and — when configured — partial discharge, helping identify insulation aging, moisture ingress, abnormal leakage current and developing insulation defects before they progress into a bushing failure.
- Suitable for power transformers, substation transformers, generator step-up transformers and other capacitive high-voltage equipment
- Configurable as an insulation monitoring system, a partial discharge monitoring system, or an integrated bushing monitoring solution
- Provides online data, alarm thresholds and historical trend records for condition-based maintenance
Why Bushing Condition Needs Continuous Monitoring
Power transformer bushings sit under high voltage stress for years at a stretch. Because capacitance, dielectric loss, leakage current and partial discharge activity all change gradually as insulation ages, a once-a-year offline test is often too infrequent to catch a developing defect before it turns into an unplanned outage.
- Capacitance and dielectric loss shifts often develop between scheduled offline test dates
- Moisture ingress, contamination and thermal stress accelerate bushing insulation aging
- Leakage current abnormalities can appear well before a bushing shows a visible fault
- An unmonitored bushing failure carries some of the highest unplanned-outage risk on a transformer
What the Bushing Monitoring System Measures
Each monitored parameter maps to a specific bushing insulation health question, so the data can be used directly for condition-based maintenance decisions rather than just raw readings.
| Objectif du suivi | État mesuré | Valeur d'entretien |
|---|---|---|
| État de l'isolation | Variation de la capacité et de la perte diélectrique | Permet d'alerter rapidement en cas de vieillissement prématuré de l'isolation |
| État du courant de fuite | Courant total et variation du courant | Permet de détecter un fonctionnement anormal des bagues |
| Activité liée aux décharges partielles | Signal PD et tendance de décharge | Alerte en cas d'apparition de défauts d'isolation |
| Surveillance à distance des actifs | Données en ligne, alertes et tendances historiques | Améliore le processus de surveillance de l'état des transformateurs |
Choose an Insulation, PD, or Integrated Configuration
The bushing monitoring system is built on the IN-205B platform and configured according to the monitoring function your project needs.
Bushing Insulation Online Monitoring
Total current, capacitance and dielectric loss monitoring — the base configuration for continuous bushing insulation condition tracking.
Insulation + Partial Discharge Integrated Monitoring
Combines bushing insulation parameters with partial discharge sensing in a single online monitoring configuration — the recommended choice when both data sets are needed.
Bushing Partial Discharge Online Monitoring
Dedicated partial discharge monitoring for transformer bushings, for projects that already track insulation parameters separately.
How Online Bushing Monitoring Works
Signal Acquisition
Sensors tap the bushing test terminal or grounding path to capture total current, capacitance and dielectric loss signals.
PD Sensing (Optional)
Where configured, partial discharge sensors capture discharge pulses related to bushing insulation defects in parallel.
Trend Processing
The monitoring host calculates capacitance and dielectric loss values, checks measurement repeatability, and builds a trend history.
Alarm & SCADA Output
Threshold alarms and trend data are output via Modbus or DL/T860 to substation automation and SCADA platforms.
What a Bushing Monitoring System Includes
A complete transformer bushing monitoring system pairs sensing hardware at the bushing with a monitoring host and a communication interface, so insulation data flows straight into your existing monitoring workflow.
- Bushing-side sensing connection at the test terminal or grounding path
- IN-205B series monitoring host — insulation, PD, or integrated signal processing
- Onboard alarm thresholds with local display and historical trend storage
- Modbus / DL/T860 output to SCADA, substation automation or asset platforms
Installation Options
- Standard 19-inch rack-mounted type — IP30 protection
- Wall-mounted outdoor type — IP55 protection
Transformer Bushing Monitoring System Specifications
Standard IN-205B series specifications — exact configuration is confirmed per project based on bushing type and monitoring function.
| Élément du cahier des charges | Configuration standard / en option |
|---|---|
| Modèle type | Série IN-205B |
| Objet de surveillance | Isolation des traversées de transformateur et état des décharges partielles |
| Paramètres de surveillance | Courant total, capacité, perte diélectrique, décharge partielle |
| Plage de mesure totale du courant | de 2 mA à 1 000 mA |
| Précision totale de la mesure du courant | ± (valeur de référence : 1% + 0,1 mA) |
| Plage de mesure de la capacité | de 100 pF à 50 000 pF |
| Précision de la mesure de la capacité | ± (valeur de référence : 1% + 1 pF) |
| Plage de mesure des pertes diélectriques | de 0,001 à 0,3 |
| Précision de la mesure des pertes diélectriques | ±(valeur standard 1% + 0,001) |
| Répétabilité des mesures | <0,2% |
| Alimentation électrique de service | CA 220 V ±101 TP3T |
| Protocole de communication | Modbus, DL/T860 |
| Température ambiante | de -40 °C à +70 °C |
| Humidité ambiante | De 0 à 95%, sans condensation |
| Indice de protection | Modèle standard pour rack 19 pouces, indice de protection IP30 ; modèle mural, indice de protection IP55 |
| Type d'installation | Configuration en rack ou murale |
Communication for Bushing Condition Monitoring Platforms
Monitoring data, alarm status and trend information can be transmitted directly into substation automation systems, transformer monitoring platforms or SCADA.
| Point de communication | Fonction | Utilisation type |
|---|---|---|
| Modbus | Transfère les données de suivi et les informations d'état | SCADA, système de surveillance local ou passerelle industrielle |
| DL/T860 | Répond aux exigences en matière de communication pour l'automatisation des postes électriques | Intégration d'une plateforme de surveillance et de protection des postes électriques |
| Sortie d'alarme | Émet un avertissement lorsque les valeurs surveillées dépassent les seuils prédéfinis | Salle d'exploitation, système de maintenance ou armoire de commande de transformateur |
| Données historiques sur les tendances | Enregistre les modifications des mesures en vue de l'évaluation de l'état | Évaluation de l'état des bagues et planification de la maintenance |
Where Bushing Monitoring Is Applied
| Demande | Besoin de suivi | Valeur du système |
|---|---|---|
| Traversée de transformateur de puissance | Surveillance en ligne de l'isolation et des courants de fuite | Alerte précoce en cas de détérioration de l'isolation des bagues isolantes |
| Sous-station haute tension | Surveillance continue des équipements capacitifs critiques | Améliore la visibilité des actifs et la réactivité en matière de maintenance |
| Transformateur élévateur pour générateur | Suivi de l'état des bagues dans des conditions de fonctionnement à forte charge | Contribue à la fiabilité des installations de production d'électricité |
| Transformateur industriel | Surveillance des équipements électriques essentiels à la production | Réduit le risque d'interruption imprévue |
| Transformateur de mesure ou parafoudre | Surveillance de l'état d'isolation des équipements capacitifs | Étend la couverture de la surveillance au-delà des traversées de transformateur |
Selection is based on transformer type, bushing quantity, monitoring function, installation method and communication requirement — our engineering team can confirm a configuration matched to your equipment.
Solutions complètes de surveillance en ligne des transformateurs
Bushing monitoring covers one insulation path on the transformer. Explore the rest of our transformer monitoring solutions to build full asset health and condition coverage.

Surveillance des transformateurs
Notre solution globale de surveillance en ligne des transformateurs, qui regroupe les données relatives à la température, à l'analyse des gaz de décomposition (DGA), aux décharges partielles (PD), aux traversées et aux transformateurs à transformateur en ligne (OLTC) dans une seule vue de surveillance de l'état.

Surveillance des décharges partielles
UHF, HFCT and ultrasonic PD sensing across the transformer, pairing naturally with bushing-level discharge monitoring.

Surveillance des gaz dissous (DGA) dans les transformateurs
Continuous fault-gas trending in transformer oil, useful for confirming whether bushing insulation issues are generating fault gases.

Suivi OLTC
Tap-changer current, temperature, vibration, torque and position monitoring, for full electrical asset health coverage.

Surveillance de la température par fibre optique
Direct winding hot-spot temperature measurement, adding a thermal-stress data layer alongside bushing insulation status.

Surveillance de la température des transformateurs
Online winding and top-oil temperature monitoring, complementing bushing and insulation condition data.
Bushing & Related Condition Monitoring Products
Our bushing monitoring hardware is factory direct and in-house engineered, and pairs naturally with our PD, OLTC and DGA monitoring products for complete transformer condition coverage.

Système de surveillance des traversées de transformateur
Model options from IN-205B insulation monitoring up to the IN-205B3 integrated bushing insulation and partial discharge configuration.

Système de surveillance des bagues
A general-purpose bushing condition monitoring platform covering capacitance, dielectric loss and leakage current.

Système de surveillance en ligne des décharges partielles
UHF, HFCT and ultrasonic PD sensing, cross-checked with bushing insulation data for a fuller diagnostic picture.

Système de surveillance DGA en ligne
Continuous fault-gas trending for transformer oil, useful when bushing insulation issues need to be cross-checked against oil chemistry.

Système de surveillance en ligne de l'OLTC des transformateurs
Tracks tap-changer current, temperature, vibration, torque and position for complete electrical asset condition monitoring.

Système de mesure de température par fibre optique
Fluorescent fiber optic sensing for direct winding hot-spot temperature, complementing bushing insulation status data.
Bushing Monitoring, Engineered and Customized In-House
We design and manufacture our bushing monitoring hardware end to end — from the sensing connection to the IN-205B monitoring host — giving us the flexibility to tailor a configuration to your bushing type, voltage class, and plant-wide condition monitoring requirements.
- In-house R&D and manufacturing of bushing insulation and PD monitoring hardware
- Configurations tailored to voltage class, monitoring function and installation type
- Rack-mounted or wall-mounted enclosure options for indoor or outdoor environments
- Assistance technique, de la consultation initiale jusqu'à la mise en service
Comment choisir un dispositif de surveillance des traversées de transformateur
Selection should be based on bushing type, monitoring objective, installation method and required communication interface.
| Élément de sélection | Éléments à vérifier |
|---|---|
| Type de transformateur | Transformateur de puissance, transformateur de générateur, transformateur industriel ou tout autre équipement haute tension |
| Nombre de bagues | Nombre de traversées et de phases à surveiller |
| Fonction de surveillance | Surveillance de l'isolation, surveillance des décharges partielles ou surveillance intégrée |
| Paramètres mesurés | Exigences en matière de surveillance du courant total, de la capacité, des pertes diélectriques et des décharges partielles |
| Méthode d'installation | Installation en rack 19 pouces ou installation murale à l'extérieur |
| Exigences en matière de communication | Connexion via Modbus, DL/T860, SCADA ou une plateforme de surveillance locale |
| Environnement du site | Armoire intérieure, poste de distribution extérieur, conditions de température et d'humidité ambiantes |
Bushing Monitoring FAQ
Qu'est-ce qu'un système de surveillance des traversées de transformateur ?
Un système de surveillance des traversées de transformateur est un dispositif de surveillance en temps réel permettant de contrôler l'état de l'isolation des traversées de transformateur à l'aide de paramètres tels que le courant total, la capacité, les pertes diélectriques et les décharges partielles.
Pourquoi la surveillance des traversées de transformateur est-elle importante ?
Les traversées de transformateur constituent des composants d'isolation haute tension essentiels. Une capacité anormale, des pertes diélectriques, un courant de fuite ou la présence de décharges partielles peuvent indiquer une détérioration de l'isolation et doivent faire l'objet d'une surveillance afin de permettre une détection précoce.
Que surveille le système ?
Le système peut surveiller le courant total, la capacité, les pertes diélectriques et les décharges partielles, en fonction du modèle choisi et de la configuration du projet.
Le système est-il capable de détecter les décharges partielles ?
Yes. Partial discharge monitoring can be selected as an independent function (IN-205B2) or integrated with bushing insulation monitoring (IN-205B3).
Le système de surveillance des bagues isolantes peut-il être connecté au système SCADA ?
Oui. Le système prend en charge des protocoles de communication tels que Modbus et DL/T860 pour l'intégration avec des systèmes de surveillance de postes électriques ou des plateformes SCADA.
Quels sont les types d'installation disponibles ?
The system can be configured as a standard 19-inch rack-mounted type (IP30) or a wall-mounted outdoor type (IP55) according to the installation environment.
What is the difference between online bushing monitoring and offline testing?
Offline testing gives a result at one point in time, usually during a scheduled maintenance window. Online bushing monitoring runs continuously while the transformer stays in service, tracking capacitance, dielectric loss and current trends instead of a single snapshot.
Does bushing monitoring relate to dissolved gas analysis (DGA)?
The two are complementary: bushing monitoring tracks the insulation and discharge condition of the bushing itself, while DGA measures fault gases dissolved in the main tank oil that certain insulation problems can generate over time.
Can bushing monitoring be applied to equipment other than transformers?
Yes. The same capacitive-equipment monitoring concept can be applied to instrument transformers and surge arresters when continuous insulation condition supervision is required.
What information is needed before selecting a bushing monitoring system?
Avant de choisir le système, il convient de vérifier le type de transformateur, le nombre de traversées, les paramètres de surveillance, les exigences en matière de décharges partielles, le protocole de communication et l'environnement d'installation.
Reconnu par les services publics et les fabricants de transformateurs du monde entier
Our bushing monitoring systems are deployed across power utilities, transformer OEMs, and industrial plants throughout North America, Europe, and Asia-Pacific.
Continuous dielectric loss trending flagged a bushing well ahead of its scheduled offline test — a clear save for our maintenance budget.
Équipe d'ingénierie des services publicsFrance
Running the integrated IN-205B3 configuration gave us insulation and PD data from the same bushing set without doubling up on hardware.
Fabricant de transformateursCorée du Sud
DL/T860 integration meant our substation automation platform picked up bushing alarms directly, with no extra gateway needed.
Gestionnaire de réseauÉtats-Unis
Not Sure Which Bushing Monitoring Configuration Fits Your Equipment?
Tell us your bushing type, quantity, and whether PD monitoring is required — our engineering team will recommend the right IN-205B configuration and, if useful, the complementary transformer monitoring solutions to pair it with.