Monitoreo integral del estado de los transformadores: temperatura, análisis de gases de descomposición (DGA), descargas parciales y evaluación del estado de los activos | WhatsApp: +86 13599070393 | Correo electrónico: [email protected]

Aplicaciones

Monitoreo de transformadores sumergidos en aceite

Monitor winding hot spots, insulating oil, dissolved gases, partial discharge, oil level, pressure, bushings, OLTC and cooling conditions to identify developing abnormalities in oil-filled transformers.

Build a monitoring configuration around the actual thermal, insulation and oil-system risks of each transformer.

Por qué es importante

Why Oil-Immersed Transformers Need More Than Temperature Monitoring

Oil-immersed transformers rely on the combined performance of the winding, oil-paper insulation, insulating oil, cooling system, tank accessories, bushings and OLTC. During continuous operation, these systems can be affected by thermal stress, electrical stress, insulation aging, oil deterioration, cooling degradation, leakage, abnormal internal pressure and discharge activity.

A normal top-oil temperature does not necessarily mean that winding hot spots, insulation degradation or developing internal faults are absent.

A comprehensive online monitoring approach combines winding temperature, oil temperature, dissolved gas analysis, partial discharge, oil level, pressure, bushing condition, OLTC condition and cooling status to build a fuller picture of transformer condition.

Monitoreo de transformadores sumergidos en aceite
Aislamiento de papel impregnado en aceite

Protecting the Oil-Paper Insulation System

Oil and cellulose insulation work together to provide electrical insulation and thermal management inside an oil-immersed transformer. Over time, excessive temperature, local overheating, moisture, electrical stress, oxidation and discharge activity can all affect this system.

Thermal and electrical abnormalities can accelerate insulation aging before obvious external symptoms appear.

  • Direct winding temperature monitoring
  • Dissolved gas analysis (DGA)
  • Monitoreo de descargas parciales
  • Oil condition monitoring
Protecting the Oil-Paper Insulation System
Bobinado

Direct Winding Hot Spot Monitoring

Top-oil temperature represents the general thermal condition of the transformer, but it may not fully represent localized winding hot spots that can develop under heavy loading, localized heating, cooling imbalance or uneven thermal distribution.

Top-oil temperature reflects the overall thermal condition, while direct winding hot spot monitoring provides information from critical internal locations.

  • Heavy loading conditions
  • Localized heating
  • Cooling imbalance
  • Accelerated insulation aging risk
Direct Winding Hot Spot Monitoring
Aceite para transformadores

Dissolved Gas Monitoring for Internal Fault Development

Transformer oil can carry chemical evidence of developing internal faults. Monitoring applications cover internal overheating, arcing, discharge activity, insulation decomposition and fault development trends.

DGA is particularly valuable for oil-immersed transformers because changes in dissolved gases can provide indications of developing thermal and electrical abnormalities inside the transformer.

Dissolved Gas Monitoring for Internal Fault Development
Sistema de aislamiento

Monitoreo de descargas parciales y del estado del aislamiento

Oil-paper insulation, windings, internal leads and other high-voltage insulation structures may develop localized defects. Partial discharge monitoring can help identify developing insulation defects, track discharge activity, observe condition trends, support maintenance prioritization and provide additional evidence alongside DGA and temperature monitoring.

Monitoreo de descargas parciales y del estado del aislamiento
Oil System

Oil Temperature, Level and Pressure Monitoring

Oil temperature, oil level and pressure are not isolated accessory measurements. Together they provide useful information about the operating condition of the oil system and transformer tank.

Temperatura del aceite

  • Overall thermal condition
  • Eficacia de enfriamiento
  • Abnormal temperature rise

Nivel de aceite

  • Oil loss
  • Leakage indication
  • Abnormal level changes

Presión

  • Abnormal internal pressure
  • Tank operating condition
  • Pressure-related abnormalities

The Transformer Oil Temperature, Level & Pressure Monitoring System integrates these measurements to support assessment of thermal conditions, oil-system status and pressure-related abnormalities.

Sistema de enfriamiento

Cooling Performance Monitoring

Transformer thermal reliability also depends on the proper operation of the cooling system, covering cooling fans, oil pumps, radiators, cooling stages, top-oil temperature and load versus temperature behavior.

Cooling degradation → reduced heat dissipation → rising oil / winding temperature → increased insulation thermal stress.

Cooling Performance Monitoring
Critical Accessories

Monitoring Critical Transformer Accessories

Bushings and OLTCs are critical components whose deterioration may affect transformer reliability even when winding and oil conditions appear normal.

Monitoreo de los bujes de los transformadores

  • Deterioro del aislamiento
  • Comportamiento dieléctrico anormal
  • Anomalías en la corriente de fuga
  • Developing bushing problems

On-Load Tap Changer Monitoring

  • Operación de conmutación
  • Condición de contacto
  • Mecanismo de accionamiento
  • Mechanical and electrical abnormalities
  • Operating trends
Mapeo de riesgos

What Can Different Monitoring Signals Tell You?

Condición observadaPosible motivo de preocupaciónUseful Monitoring
Aumento de la temperatura del devanadoMay be associated with overload, localized heating or a cooling problemWinding hot spot monitoring
Abnormal top-oil temperatureMay indicate increased thermal load or reduced cooling performanceOil temperature + cooling monitoring
Tendencia anómala en los gases disueltosMay indicate a developing thermal or electrical faultDGA
Increasing partial discharge activityMay indicate a developing insulation defectMonitoreo de descargas parciales
Falling or abnormal oil levelMay be associated with oil loss, leakage or an abnormal oil-system conditionOil level monitoring
Abnormal pressureMay indicate an abnormal tank or internal operating conditionPressure monitoring
Cooling equipment abnormalityCan lead to reduced heat dissipationCooling + temperature monitoring
Bushing abnormalityMay indicate developing insulation deteriorationMonitoreo de bujes
OLTC operating abnormalityPodría indicar un problema mecánico o eléctricoOLTC monitoring

These signals support assessment and maintenance prioritization rather than providing a definitive diagnosis on their own.

Tipos de proyectos

Monitoring for New and Existing Oil-Immersed Transformers

Nuevos proyectos de transformadores

Monitoring functions can be planned during transformer design, manufacturing or commissioning.

  • Embedded winding hot spot sensing
  • DGA
  • Descarga parcial
  • Monitoreo de bujes
  • OLTC monitoring
  • Oil temperature / level / pressure
  • Cooling monitoring
  • Integración de SCADA

Monitoring can be incorporated into the transformer project before commissioning.

Modernización de transformadores existentes

Existing oil-immersed transformers can often be upgraded with additional monitoring functions according to the installed equipment and available interfaces.

  • Integración de sensores existentes
  • Additional temperature monitoring
  • Modernización de DGA
  • PD monitoring
  • Oil level / pressure monitoring
  • Monitoreo de bujes
  • OLTC monitoring
  • Cooling status monitoring
  • Communication integration

Retrofit projects do not necessarily require replacement of the entire existing monitoring infrastructure, depending on existing equipment and project conditions.

Not Sure Which Parameters Need Continuous Monitoring?

Tell us your transformer type, rating, existing sensors, current monitoring equipment and the conditions you want to monitor. We can help identify a suitable monitoring configuration for your project.

Configuration Examples

Choose Monitoring by Transformer Risk, Not by a Fixed Package

Thermal Risk Focus

Typical concerns: high loading, temperature rise, cooling performance. Relevant monitoring: winding hot spot, oil temperature, cooling system.

Internal Fault Focus

Typical concerns: aging transformer, previous abnormalities, insulation concerns, critical service. Relevant monitoring: DGA, partial discharge, temperature.

Monitoreo integral del estado

Typical concerns: critical power transformer, high-value asset, remote / unattended operation, higher reliability requirement. Potential monitoring: winding temperature, DGA, PD, bushing, OLTC, oil temperature / level / pressure, cooling.

These are configuration examples rather than fixed packages. The final monitoring configuration should be selected according to transformer condition, criticality, existing instrumentation and project objectives.

Arquitectura del sistema

From Transformer Sensors to SCADA

Monitoring functions can be integrated according to existing sensors, installed devices, transformer condition and the customer's control system architecture.

Transformador sumergido en aceite
Temperatura del bobinado
DGA
Descarga parcial
Temperatura del aceite
Nivel de aceite
Presión
Buje
OLTC
Enfriamiento
Unidades de monitoreo y adquisición de datos
Comunicación / Puerta de enlace
SCADA / Centro de control / Plataforma de monitoreo remoto
Guía de selección

How to Select an Oil-Immersed Transformer Monitoring Configuration

Selection should be guided by factors such as:

  • Tipo de transformador
  • Potencia nominal del transformador
  • Nivel de voltaje
  • Age and operating history
  • Asset criticality
  • Condición de carga
  • Sensores existentes
  • Equipos de monitoreo existentes
  • Known risk points
  • Parámetros de monitoreo requeridos
  • Sistema SCADA / de control existente
  • New-build or retrofit project
  • Estrategia de mantenimiento

The most effective monitoring system is not necessarily the one with the largest number of sensors, but the one configured around the transformer's actual risks and maintenance objectives.

Preguntas frecuentes

Oil-Immersed Transformer Monitoring FAQ

What should be monitored on an oil-immersed transformer?

Depending on the transformer's importance and condition, monitoring can cover winding hot spots, oil-paper insulation, dissolved gases, partial discharge, oil temperature, oil level, pressure, bushing condition, OLTC condition and cooling system status.

Is top-oil temperature enough to monitor transformer thermal condition?

Top-oil temperature reflects the overall thermal condition, but it may not fully represent localized winding hot spots. Direct winding hot spot monitoring provides additional information from critical internal locations.

Why is winding hot spot monitoring important?

Localized heating under heavy loading or cooling imbalance can accelerate insulation aging at specific points that top-oil temperature alone does not fully represent.

Why is DGA particularly useful for oil-immersed transformers?

Transformer oil can carry chemical evidence of developing internal faults, so tracking dissolved gas trends can provide indications of developing thermal and electrical abnormalities inside the transformer.

¿Cuál es la diferencia entre el monitoreo de DGA y el de descargas parciales?

DGA tracks fault-related gases dissolved in the transformer oil, while partial discharge monitoring tracks electrical discharge activity directly in the insulation system. The two methods provide different evidence and are often used together.

Why should transformer oil level and pressure be monitored?

Oil level and pressure can help identify oil loss, leakage indication, abnormal level changes and abnormal tank operating conditions.

Can an existing oil-immersed transformer be upgraded with online monitoring?

In many cases, yes. Retrofit projects do not necessarily require replacement of the entire existing monitoring infrastructure, depending on existing equipment and project conditions.

Can existing transformer sensors be integrated into a new monitoring system?

Existing sensors can often be integrated depending on their signal type, installed devices and available interfaces.

¿Se pueden conectar los datos de monitoreo de los transformadores al sistema SCADA?

Yes. Monitoring functions can be integrated with SCADA, control center or remote monitoring platforms via a communication and gateway layer.

Does every oil-immersed transformer need DGA, PD, bushing and OLTC monitoring?

No. The final monitoring configuration should be selected according to transformer condition, criticality, existing instrumentation and project objectives, rather than a fixed package.

How should monitoring functions be selected for an existing transformer?

Consider transformer type, rating, age and operating history, asset criticality, loading condition, existing sensors and monitoring equipment, known risk points, required monitoring parameters, existing SCADA / control system and maintenance strategy.

Planning a New Transformer or Retrofit Project?

Send us your transformer type, rating, existing instrumentation, monitoring requirements and system integration needs. We can help identify suitable monitoring points and develop a monitoring architecture around the actual requirements of your project.

Solicita una cotización

Solicita una cotización

WhatsApp
Contáctenos

[email protected]