Transformer Monitoring Built Around Your Specification
OEM/ODM support, configurable fiber optic temperature and multi-parameter monitoring products, and technical response fast enough to keep your project on schedule.
OEM & ODM
Proven monitoring platforms branded and configured for your own product line.
Product Customization
Channels, sensors, hosts, enclosures and I/O matched to your application.
تكامل الأنظمة
Single-parameter or combined monitoring, delivered as one coordinated scope.
Fast Technical Response
Requirements reviewed and configurations confirmed without back-and-forth delay.
OEM & ODM for Monitoring Products
We do not start from a blank sheet. Established platforms and manufacturing processes are configured, branded and documented to your specification, so you carry the product under your own identity with proven technology behind it.
- Customer branding and nameplates
- Model naming and part numbering
- Enclosure customization
- Interface and I/O configuration
- Customer-specific documentation
- Packaging customization
- Project-specific scope of supply
- Repeat-order configuration control
Used by OEM manufacturers, panel builders and system integrators supplying transformer and power equipment markets.
Fiber Optic Temperature Monitoring Customization
Our fiber optic products use fluorescent point temperature sensing rather than distributed temperature sensing (DTS). Because measurement is point-based, channel count, probe type and host configuration follow the exact monitoring points in your design — from a handful of points up to 64 channels.
- عدد القنوات1–64, by product
- Sensor / probe typeWinding, oil, surface
- طول الأليافTo installation layout
- Monitoring hostWith or without display
- Alarm thresholdsConfigurable
- OutputsRelay, 4–20 mA
- التواصلRS485 / Modbus
- EnclosurePanel, rack or cabinet
Typical use: transformer winding hotspots, oil-immersed and dry-type transformers, high-voltage equipment, generator and motor windings, and other EMI-intensive environments where electrical sensors are unsuitable.
Monitoring Hosts & Hardware Configuration
Hosts and supporting hardware are configured around channel count, mounting method and interface requirements.
Channel Quantity
Set to the number of monitoring points your equipment requires.
Mounting Method
Panel-mounted, rack-mounted or cabinet-integrated.
مصدر الطاقة
Matched to available site or panel power.
Alarm & Relay Outputs
Thresholds and outputs aligned to your control logic.
Communication Ports
RS485 with Modbus, configured to project requirements.
Enclosure Size
Dimensions and layout adapted to available panel space.
Display Option
Local display included or omitted as the site requires.
جمع البيانات
Parameters and sampling set for the monitoring task.
Exact specifications vary by product and are confirmed in technical review against your project requirements.
Integrated Transformer Monitoring
Select one parameter or combine several into a multi-parameter system. The configuration is built around what matters for your equipment and site, not around a fixed package.
Communication & SCADA / PLC Integration
Compatible interfaces, protocol documentation and signal-mapping coordination so your monitoring hardware reaches the control room cleanly.
Monitoring Products
واجهة الاتصال
Customer PLC / SCADA
INNO supplies the interfaces, protocol and register documentation, wiring reference material and technical coordination on signal mapping. Configuration of your SCADA platform and on-site PLC programming stay with your engineering team. *TCP available where supported by the selected product.
New Projects & Retrofit Applications
Configuration differs depending on whether monitoring goes into a new transformer or onto equipment already in service.
مشاريع جديدة
- Product selection by number of monitoring points
- Configuration matched to the project communication system
- Configuration matched to cabinet layout and mounting
- Monitoring functions combined into one defined parameter set
Retrofit & Upgrade
- Monitoring points added to transformers in service
- Integration with an existing SCADA system
- Modernization of ageing monitoring functions
- Configuration for space-limited installations and different I/O
How a Project Moves Forward
Six steps from first enquiry to integration support — with a single technical contact throughout.
Requirement Review
Your application and monitoring needs are assessed.
Product Selection
Suitable products identified for your parameters.
Technical Confirmation
Configuration details confirmed with you directly.
Configuration & Drawings
Product configuration and drawings prepared.
Quotation
Pricing issued against the confirmed configuration.
Integration Support
Technical support continues through your integration work.
Send these details and we can respond in one round instead of three:
Technical Documentation & Pre-Sales Support
Everything your engineering, procurement and tender teams need during evaluation.
Datasheets
Specifications for evaluation and selection.
Wiring Diagrams
Reference drawings for electrical connection.
Installation Drawings
Dimensional and layout drawings for planning.
Protocols & Registers
Protocol and register tables for SCADA/PLC mapping.
Selection Support
Guidance matching products to your application.
Tender Documentation
Technical material to support your submissions.
Configuration Confirmation
Written sign-off of the agreed configuration.
Quality & Test Records
Factory test documentation on request.
Relied on by OEM manufacturers, system integrators, EPC contractors, utilities, transformer manufacturers and industrial end users.
After Delivery
Support does not stop at shipment. One technical contact stays with the product for its service life.
Why Work with INNO
Configured to Your Points
Products follow your monitoring layout, not the other way around.
Multi-Parameter Capability
Temperature, DGA, PD, bushing and OLTC from one supplier.
OEM / ODM Ready
Established platforms branded and documented for your product line.
SCADA / PLC Compatible
Standard interfaces backed by full protocol documentation.
Direct Technical Contact
Engineers answer engineers — no relayed questions.
Support for the Long Term
Parts, configuration and troubleshooting years after delivery.
الأسئلة الشائعة
Does INNO manufacture transformers?
No. We develop monitoring products for transformers and other power equipment. The transformer itself is not our product.
What is the difference between your OEM and ODM support?
Both use the same proven platforms. OEM focuses on branding, nameplates and documentation under your identity; ODM extends into configuring the product itself to your specification.
Is your fiber optic temperature monitoring the same as DTS?
No. We use fluorescent fiber optic point sensing, which measures at defined probe locations rather than continuously along the fiber as distributed temperature sensing does.
How many channels can a fiber optic host support?
Depending on the product and configuration selected, from a small number of points up to 64 channels.
Can your products integrate with our existing SCADA or PLC?
Yes. We supply RS485 with Modbus, protocol documentation and register tables. Configuration of your SCADA platform and PLC programming is carried out by your own team.
Can you support retrofit projects on transformers already in service?
Yes. Products can be configured to add monitoring points, replace ageing monitoring functions or connect into a SCADA system already running on site.
What information do you need to recommend a configuration?
Equipment type, monitoring parameters, number of points, communication interface, power supply and installation method are usually enough for a first proposal.
Do you provide on-site installation or commissioning?
This page covers product supply, configuration and technical documentation. Contact us to discuss on-site scope for your specific project.
Do you accept sample or small-quantity orders for evaluation?
Yes. Evaluation quantities are common before a series project or an OEM programme starts, and are quoted the same way as production orders.
Which documentation is delivered with an order?
Datasheets, wiring and installation drawings, communication protocol and register tables, and written confirmation of the agreed configuration.
Tell Us What You Need to Monitor
Send your project details and we will come back with product options, a configuration proposal and a quotation.
- نوع المعدات
- معايير الرصد
- عدد النقاط
- واجهة الاتصال
- مصدر الطاقة
- طريقة التركيب
- OEM / ODM requirements
- Project quantity
Tell us your application, monitoring points, communication requirements, or OEM/ODM needs. Based on the information you provide, our team can help identify a suitable product configuration and reduce repeated technical clarification.
Whether you need a standard product, channel customization, a customized monitoring host, or an integrated transformer monitoring solution, you can send us your requirements directly.
The more details you provide, the easier it is for us to recommend a suitable configuration.
1. Can you customize monitoring products?
Yes. Channel count, sensors, host configuration, communication interfaces, outputs, and enclosure options can be adjusted based on project requirements.
2. Do you support OEM and ODM?
Yes. We support branding, labels, model configuration, documentation, packaging, and project-specific customization.
3. What information should I provide?
Please provide the equipment type, monitoring parameters, number of points, communication interface, power supply, and any customization requirements.