Система мониторинга проходных изоляторов трансформатора
Этот transformer bushing monitoring system is designed for online insulation condition monitoring of high-voltage transformer bushings. It monitors key bushing parameters such as total current, capacitance, dielectric loss and partial discharge to help identify insulation aging, moisture ingress, abnormal leakage current and developing insulation defects.
The system is suitable for power transformers, substation transformers and other capacitive high-voltage equipment where continuous bushing condition monitoring is required. It can be configured as an insulation monitoring system, a partial discharge monitoring system or an integrated bushing monitoring solution.

Online Bushing Monitoring System for Power Transformers
Power transformer bushings operate under high voltage stress for long periods. Changes in capacitance, dielectric loss, leakage current or partial discharge activity may indicate bushing insulation deterioration. An online bushing monitoring system helps operators track these parameters during normal transformer operation without relying only on periodic offline testing.
| Monitoring Purpose | Measured Condition | Стоимость технического обслуживания |
|---|---|---|
| Insulation condition | Capacitance and dielectric loss change | Supports early insulation aging warning |
| Leakage current status | Total current and current variation | Helps identify abnormal bushing operating condition |
| Partial discharge activity | PD signal and discharge trend | Provides warning for developing insulation defects |
| Remote asset monitoring | Online data, alarms and historical trends | Improves transformer condition monitoring workflow |
Transformer Bushing Insulation Monitoring
Transformer bushing insulation monitoring focuses on the operating condition of capacitive bushings. By continuously tracking capacitance, dielectric loss and leakage current, the system helps detect changes that may be related to internal insulation deterioration, moisture, contamination or thermal stress.
The monitoring data can be used for condition-based maintenance, bushing risk assessment and transformer operation review. For critical transformers, continuous insulation monitoring can reduce the risk of unexpected bushing failure.
Bushing Monitoring System for Capacitance and Dielectric Loss

Capacitance and dielectric loss are important parameters for evaluating the insulation condition of transformer bushings. The bushing monitoring system measures these values online and records trend changes over time.
| Параметр мониторинга | Значение | Typical Concern |
|---|---|---|
| Total current | Current flowing through the bushing insulation path | Abnormal leakage current increase |
| Capacitance | Electrical capacitance of capacitive bushing insulation | Insulation structure or dielectric condition change |
| Dielectric loss | Insulation loss factor for bushing condition evaluation | Moisture, aging, contamination or insulation degradation |
| Trend repeatability | Stability of repeated online measurements | Long-term monitoring reliability |
Transformer Bushing Partial Discharge Monitoring
Transformer bushing partial discharge monitoring is used to detect PD activity related to bushing insulation defects. Partial discharge may occur when insulation deterioration, internal voids, surface contamination or electric field concentration develops inside or around the bushing insulation system.
The system can be configured with partial discharge monitoring functions for bushing PD signal acquisition, alarm output and trend analysis. For projects requiring both insulation parameters and PD activity, an integrated bushing monitoring configuration can be selected.
Transformer Bushing Monitoring System Model Options

The transformer bushing monitoring system can be configured according to the required monitoring function. Different model options are available for insulation monitoring, partial discharge monitoring or combined monitoring.
| Модель | Тип продукта | Main Monitoring Function |
|---|---|---|
| IN-205B | Transformer Bushing Insulation Online Monitoring System | Total current, capacitance and dielectric loss monitoring |
| IN-205B2 | Transformer Bushing Partial Discharge Online Monitoring System | Partial discharge monitoring for transformer bushings |
| IN-205B3 | Transformer Bushing Insulation and Partial Discharge Integrated Online Monitoring System | Integrated bushing insulation and PD monitoring |
Power Transformer Bushing Condition Monitoring
Power transformer bushing condition monitoring helps utilities and industrial users evaluate bushing insulation status without interrupting transformer operation. The system collects online data, compares measurement trends and provides alarms when abnormal values are detected.
Besides transformer bushings, the monitoring concept can also be applied to capacitive high-voltage equipment such as instrument transformers and surge arresters when the project requires continuous insulation condition supervision.
Technical Specifications of the Transformer Bushing Monitoring System
| Пункт спецификации | Стандартная / Дополнительная конфигурация |
|---|---|
| Название продукта | Система мониторинга проходных изоляторов трансформатора |
| Типовая модель | IN-205B series |
| Объект мониторинга | Transformer bushing insulation and partial discharge condition |
| Параметры мониторинга | Total current, capacitance, dielectric loss, partial discharge |
| Total current measurement range | 2mA to 1000mA |
| Total current measurement accuracy | ±(standard reading 1% + 0.1mA) |
| Capacitance measurement range | 100pF to 50000pF |
| Capacitance measurement accuracy | ±(standard reading 1% + 1pF) |
| Dielectric loss measurement range | 0.001 to 0.3 |
| Dielectric loss measurement accuracy | ±(standard reading 1% + 0.001) |
| Measurement repeatability | <0.2% |
| Рабочий источник питания | AC 220 В ±101 TP3T |
| Протокол связи | Modbus, DL/T860 |
| Температура окружающей среды | от -40 °C до +70 °C |
| Влажность окружающей среды | 0 to 95%, non-condensing |
| Protection rating | Стандартный 19-дюймовый корпус для установки в стойку, класс защиты IP30; настенный корпус, класс защиты IP55 |
| Тип установки | Конфигурация для монтажа в стойку или на стену |
SCADA Communication for Bushing Monitoring System
The system supports communication with upper-level monitoring platforms through standard communication protocols. Monitoring data, alarm status and trend information can be transmitted to substation automation systems, transformer monitoring platforms or SCADA systems.
| Communication Item | Функция | Типичные области применения |
|---|---|---|
| Modbus | Transfers monitoring data and status information | SCADA, local monitoring system or industrial gateway |
| DL/T860 | Обеспечивает соответствие требованиям к каналам связи в системах автоматизации подстанций | Substation monitoring and protection platform integration |
| Alarm output | Provides warning when monitored values exceed preset thresholds | Operation room, maintenance system or transformer control cabinet |
| Historical trend data | Records measurement changes for condition review | Bushing condition assessment and maintenance planning |
Applications of Transformer Bushing Monitoring
The transformer bushing monitoring system is suitable for critical transformer assets where bushing failure risk needs to be reduced through continuous online monitoring. It can support utilities, substations, power plants and industrial electrical systems.
| Заявка | Необходимость мониторинга | Системная стоимость |
|---|---|---|
| Power transformer bushing | Online insulation and leakage current monitoring | Early warning for bushing insulation deterioration |
| High-voltage substation | Continuous monitoring of critical capacitive equipment | Improves asset visibility and maintenance response |
| Generator step-up transformer | Bushing condition tracking under high-load operation | Supports reliability of power generation assets |
| Industrial transformer | Monitoring for important production power supply equipment | Reduces risk of unplanned outage |
| Instrument transformer or surge arrester | Capacitive equipment insulation condition monitoring | Extends monitoring coverage beyond transformer bushings |
How to Select a Transformer Bushing Monitor
Selection should be based on the bushing type, monitoring objective, installation method and required communication interface. For projects that need both insulation and partial discharge monitoring, an integrated model can be selected.
| Элемент выбора | Что необходимо подтвердить |
|---|---|
| Тип трансформатора | Power transformer, generator transformer, industrial transformer or other high-voltage equipment |
| Bushing quantity | Number of bushings and phases to be monitored |
| Monitoring function | Insulation monitoring, partial discharge monitoring or integrated monitoring |
| Measured parameters | Total current, capacitance, dielectric loss and PD monitoring requirement |
| Способ установки | 19-inch rack installation or wall-mounted outdoor installation |
| Communication requirement | Modbus, DL/T860, SCADA or local monitoring platform connection |
| Site environment | Indoor cabinet, outdoor substation, ambient temperature and humidity condition |
Frequently Asked Questions About Transformer Bushing Monitoring
What is a transformer bushing monitoring system?
A transformer bushing monitoring system is an online monitoring device used to monitor the insulation condition of transformer bushings through parameters such as total current, capacitance, dielectric loss and partial discharge.
Why is transformer bushing monitoring important?
Transformer bushings are critical high-voltage insulation components. Abnormal capacitance, dielectric loss, leakage current or partial discharge activity may indicate insulation deterioration and should be monitored for early warning.
What does the system monitor?
The system can monitor total current, capacitance, dielectric loss and partial discharge depending on the selected model and project configuration.
Can the system monitor partial discharge?
Yes. Partial discharge monitoring can be selected as an independent function or integrated with bushing insulation monitoring.
Can the bushing monitoring system connect to SCADA?
Yes. The system supports communication protocols such as Modbus and DL/T860 for integration with substation monitoring systems or SCADA platforms.
What installation types are available?
The system can be configured as a standard 19-inch rack-mounted type or a wall-mounted type according to the installation environment.
Какая информация необходима перед выбором?
Transformer type, bushing quantity, monitoring parameters, partial discharge requirement, communication protocol and installation environment should be confirmed before selecting the system.
Transformer Bushing Monitoring System for Online Insulation Protection
Этот transformer bushing monitoring system provides online bushing insulation monitoring, capacitance and dielectric loss tracking, leakage current monitoring and optional partial discharge monitoring for high-voltage transformer assets. It is suitable for power transformer bushings, substations and other capacitive equipment requiring continuous condition monitoring and early fault warning.